14215700-IG, Edition 8.0
April 2018, Original document
188
Configuring a Backup Spectralink IP-DECT Server 6500
On the backup Spectralink IP-DECT Server 6500 only basic network settings and redundancy set-
tings need to be configured. All other settings are retrieved from the master Spectralink IP-DECT
Server 6500.
1. Ensure that the Redundancy License is installed, and configured with basic network settings.
License installation requires reboot of system.
2. Click Configuration, and then click Redundancy.
3. On the Redundancy Configuration page, enter the following data:
Field Setting
Redundancy Configuration - Node type
Single If selected, this will disable redundancy and configure for
stand alone (normal single server solution).
Select Single, if this device is to be a normal single
server solution.
Master If enabled, this will enable redundancy and configure the
device as master server. The system will be controlled by
this device.
Select Master, if this device is to be the master server.
Slave If enabled, this will enable redundancy and configure the
device as backup (slave) server. The device will be con-
trolled by a master server.
Select Slave, if this device is to be the backup server.
Redundancy Configuration - Peer node
Address If master server, enter the fixed IP address or hostname
for the backup Spectralink IP-DECT Server 6500.
If backup server, enter the fixed IP address or hostname
for the master Spectralink IP-DECT Server 6500.
Spectralink IP-DECT Server 200/400/6500 Installation and Configuration Guide