13 - 34 DS7708 2D Vertical Slot Scanner Product Reference Guide
OCR Template (continued)
This operator combined with others defines a string of characters to extract from the scanned data. The string
extract is structured as follows:
CbPe
Where:
C is the string extract operator
b is the string begin delimiter
P is the category (one or more numeric or alpha characters) describing the string representation
e is the string end delimiter
Values for b and e can be
any scannable character. They are included in the output stream.
Template Incoming data Output
C>A> XQ3>ABCDE> >ABCDE>
->ATHRUZ>123 >ATHRUZ>
1ABCZXYZ No
Output
Ignore to End of Field (D)
D
This operator causes all characters after a template to be ignored. Use this
as the last character in a template
expression. Examples for the template 999D:
Template Incoming data Output
999D 123-PED 123
357298 357
193 193
Skip Until (P1)
P