TimeHub 5500 TL1 Reference Manual
Performance Monitoring
097-55501-02 Issue 5: June 2003
SSSSSSSSSSS SSSS S SSSSS SSSSSSS S SSS S SSSSS S
4
Latest Maximum Relative Time Interval Error (cont’d)
Table G lists LMRTIE measurements and the measurement time period for an
input port.
Command Example:
RTRV-PM::CLK-4:SC1::LMRTIE;
The response to the command in this example displays LMRTIE information about
input port 4.
Parameter Value Description
<meas time> Measurement time in which data was collected. Once the measurement time
reaches 24 h, data older than 24 h will be lost as new data is collected.
Table G. LMRTIE Measurements and Time Periods for Single Input Port
Measurement
Observation Time
First Data
Available After Updated Every
Includes Data
from Last
LMRTIE-1S 1 s 1 s 1 s
LMRTIE-1M 1 min 1 min 1 min
LMRTIE-15M 15 min 15 min 15 min
LMRTIE-30M 30 min 15 min 30 min
LMRTIE-1H 1 h 15 min 1 h
LMRTIE-2H 2 h 15 min 2 h
LMRTIE-8H 8 h 15 min 8 h
LMRTIE-24H 24 h 15 min 24 h

Table of Contents

Other manuals for Symmetricom TimeHub 5500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom TimeHub 5500 and is the answer not in the manual?

Symmetricom TimeHub 5500 Specifications

General IconGeneral
BrandSymmetricom
ModelTimeHub 5500
CategoryData Loggers
LanguageEnglish

Related product manuals