TimeHub 5500 TL1 Reference Manual
205
Performance Monitoring
097-55501-02 Issue 5: June 2003
2
5
3
SSSSSSSSSSSS SSSS S SSSSS SSSSSSS S SSS S SSSSS
44
Latest Maximum Relative Time Interval Error (cont’d)
Response Example:
SYMMBITS 01-05-31 10:57:58
M SC1 COMPLD
"CLK-4:LMRTIE-1S,2.000000,COMPL,,,75-MIN"
"CLK-4:LMRTIE-1M,2.000000,COMPL,,,75-MIN"
"CLK-4:LMRTIE-15M,2.000000,COMPL,,,75-MIN"
"CLK-4:LMRTIE-30M,2.000000,COMPL,,,75-MIN"
"CLK-4:LMRTIE-1H,2.000000,COMPL,,,75-MIN"
"CLK-4:LMRTIE-2H,NA,NA,,,75-MIN"
"CLK-4:LMRTIE-8H,NA,NA,,,75-MIN"
"CLK-4:LMRTIE-24H,NA,NA,,,75-MIN"
;
The response in this example shows that LMRTIE data has been collected over the
past 75 minutes (known as measurement time), and LMRTIE values have been
calculated for observation times of 1 second, 1 minute, 15 minutes, 30 minutes,
and 1 hour. The values for observation times 2, 8, and 24 hours are not yet
available because the system has not been running long enough to collect that
data. They will become available as the system continues to collect data.

Table of Contents

Other manuals for Symmetricom TimeHub 5500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom TimeHub 5500 and is the answer not in the manual?

Symmetricom TimeHub 5500 Specifications

General IconGeneral
BrandSymmetricom
ModelTimeHub 5500
CategoryData Loggers
LanguageEnglish

Related product manuals