1
TimeHub 5500 TL1 Reference Manual
207
Performance Monitoring
097-55501-02 Issue 5: June 2003
2
5
3
SSSSSSSSSSSS SSSS S SSSSS SSSSSSS S SSS S SSSSS
44
Maximum Relative Time Interval Error (cont’d)
Table H lists MRTIE measurements and the measurement time period for an input
port.
Command Example:
RTRV-PM::CLK-4:SC1::MRTIE;
The response to the command in this example displays MRTIE information about
input port 4.
Parameter Value Description
<meas time> Measurement time in which data was collected. Once the measurement time
reaches 24 h, data older than 24 h will be lost as new data is collected.
Table H. MRTIE Measurements and Time Periods for Single Input Port
Measurement
Observation Time
First Data
Available After Updated Every
Includes Data
from Last
MRTIE-1S 15 min 15 min 24 h
MRTIE-1M 15 min 15 min 24 h
MRTIE-15M 15 min 15 min 24 h
MRTIE-30M 30 min 15 min 24 h
MRTIE-1H 1 h 15 min 24 h
MRTIE-2H 2 h 15 min 24 h
MRTIE-8H 8 h 15 min 24 h
MRTIE-24H 24 h 15 min 24 h

Table of Contents

Other manuals for Symmetricom TimeHub 5500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom TimeHub 5500 and is the answer not in the manual?

Symmetricom TimeHub 5500 Specifications

General IconGeneral
BrandSymmetricom
ModelTimeHub 5500
CategoryData Loggers
LanguageEnglish

Related product manuals