TimeHub 5500 TL1 Reference Manual
Commands
097-55501-02 Issue 5: June 2003
SSSSSSSSSSS SSSS S SSSSS SSSSSSS S SSS S SSSSS S
2
Retrieve Equipment (cont’d)
Note:
For detailed descriptions of keywords, see the Keywords chapter.
RTRV-EQPT[-TSG]:[<tid>]:[<aid>]:<ctag>:::
PARAMETER=<measurement>;
Note:
For detailed descriptions of keywords, see the Keywords chapter.
Command Examples:
RTRV-EQPT::CLK:SC1:::PARAMETER=SYNCMDE;
The command in this example displays the selection algorithm setting.
Parameter Value Variables Description
<event> TRAOOR Event
<value> See the Keywords chapter
Parameter Value Variables Description
<aid> CLK Clock card. This parameter is
optional.
IMC Management card. This parameter is
optional.
Sa-OUTb a = 1 Shelf number. This parameter is not
optional.
b = A, B, C, or D Output driver card letter. This
parameter is not optional.
<measurement> FFOF Fractional Frequency Offset
LMRTIE Latest Maximum Relative Time Interval
Error
MRTIE Maximum Relative Time Interval Error
SPRD Frequency Spread
TDEV Time Deviation
TIE Time Interval Error
<value> See the Keywords chapter

Table of Contents

Other manuals for Symmetricom TimeHub 5500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom TimeHub 5500 and is the answer not in the manual?

Symmetricom TimeHub 5500 Specifications

General IconGeneral
BrandSymmetricom
ModelTimeHub 5500
CategoryData Loggers
LanguageEnglish

Related product manuals