X35 Monitor Air Seeder Setup
6.78
4. Button B - allows you to choose the function
for this button from the following options:
a. Not Assigned - this button has no function.
b. Lift Master Control - will lift & lower
the openers if that feature is enabled and
connected.
c. Drill Lift Track Master - enables or
disables track master which sets the lift/
lower state to track the master switch state.
d. Decrease Pack Master Value - will
decrease the Pack Master value by the
preset.
e. Decrease Tank Rate - will decrease the
tank rate by the preset. When selected,
additional settings that allows the user to
select which tank rate will be decreased, in
the Tank Rate Change Mode, will become
available, refer to Steps 7 & 8 & Figure
6.99.
f. Pack Master Control - engages &
disengages Pack Master.
g. Liquid/NH3 Manual Override - changes
between VRC, auto and manual mode for
the Liquid/NH3 tank.
h. Fill All Tanks - adds product weight to
each tank, based on 100% tank volume
used and density of the product in that
specific tank (hold button until all 3 LED
light colors flash then goes back to green).
i. Quick Depth Adjustment (QDA) - raises
& lowers the QDA. Only available for the
3420 drill.
5. Button C - allows you to choose the function
for this button from the following options:
a. Not Assigned - this button has no function.
b. Prime - can be used to run meters for a
preload time or as long as the button is
held to check runs.
c. Lift Master Control - will lift & lower
the openers if that feature is enabled and
connected.
d. Drill Lift Track Master - enables or
disables track master which sets the lift/
lower state to track the master switch state.
e. Pack Master Control On/Off - engages &
disengages Pack Master.
f. Liquid/NH3 Manual Override - changes
between VRC, auto and manual mode for
the Liquid/NH3 tank.
g.
Fill All Tanks -
adds product weight to
each tank, based on 100% tank volume
used and density of the product in that
specific tank (hold button until all 3 LED
light colors flash then goes back to green).
h. Quick Depth Adjustment (QDA) - raises
& lowers the QDA. Only available for the
3420 drill.
6. Tank Keys - allows you to select tank controls:
a. Virtual - means the X35 console only will
be used to control the tank switches.
b. Keypad - mans the switchbox will be used
to control the tank switches.
c. Keypad and Virtual - both, the X35
console and the in-cab switchbox will be
used to control the tank switches.
7. Tank Rate Change Mode - allows you to
select which tanks will be controlled when the
increase/decrease tank rate button is used. The
available options are:
a. All Tanks - refers to all enabled tanks.
b. Active Tanks - refers to only tanks that
have the switch turned on.
c. Selected Tanks - brings up another tab
that allows you to pick specific tank(s),
refer to Step 8.
8. Select Tank - allows you to select specific
tank(s) that will be controlled when the
increase/decrease tank rate button is used.
Note
Unused tank buttons and unassigned buttons will
have no LEDs lit up.