X35 Monitor Air Seeder Setup
6.79
6.8.2.2 On Frame (calibration) SwitchBox
1. Keypad ID - allows you to select the on
frame switchbox.
a. When selected, it will display a drop down
list with switchbox IDs.
b. If there is no switchbox used, select none.
2. Button A - allows you to choose the function
for this button from the following options:
a. Not Assigned - this button has no function.
b. Calibration Mode On/Off - will enter/exit
calibration mode.
i. When in calibration mode, the on
frame switchbox can be used to
control metering augers, as well as
to run meters to check runs when
the unit is stationary. The X35
needs to be on the seeder controller
screen for this to work. (tap button
to enter calibrate; to exit calibrate
need to hold button until all 3 LED
light colors flash then goes back to
amber).
c. Quick Depth Adjustment (QDA) - raises
& lowers the QDA. Only available for the
3420 drill.
3. Button B - allows you to choose the function
for this button from the following options:
a. Not assigned - this button has no function.
b. Tank Fill Mode On/Off - will enter fill
mode.
i. When in fill mode, the on frame
switchbox can be used to activate
tanks as they are filled to apply the
added weight to them. The X35
needs to be on the seeder controller
screen for this to work and LED
needs to be amber. (tap button to
enter fill mode and LED will go
green)
c. Lift Master Control - will lift & lower
the openers if that feature is enabled and
connected.
d. Quick Depth Adjustment (QDA) - raises
& lowers the QDA. Only available for the
3420 drill.
4. Button C - on the on frame (calibration)
switchbox this button always functions as the
prime/reset button.
a. In calibration press to reset meter pulses.
(amber LED indicates there are pulses
detected, red indicates pulses have been
cleared)
b. When not in calibration this button can be
used to prime the meters. They will run
for the preset time if the button is tapped.
If the button is held they will continue
running.
6.6.2.2.1 Switchbox LED status:
1. Tank buttons
Red - tanks are switched off
Amber - tanks are switched on but master is
off
Green - tanks are switched on and master is
on
2. Master button
Red - master is not ready (something is
preventing master turning on, see status
window)
Amber - master is ready and can be turned on
Green - master is on
3. Lift Master button
Red - Lift Master is shut off
Amber - Lift Master is turned on but openers
are in the lifted position
Green - Openers are in the lowered position