EasyManuals Logo

Unipulse F701-C User Manual

Unipulse F701-C
189 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #46 background imageLoading...
Page #46 background image
3.METHODS OF SETTING
35
- External Function Selection
- Setting Value LOCK
(For details, please refer to "8-1" on P.109.)
- Restriction on the Tare Subtraction Function
(For details, please refer to "5-14" on P.66.)
BCD data update rate
7 : 1 times/sec.
6 : 2 times/sec.
5 : 5 times/sec.
4 : 10 times/sec.
3 : 20 times/sec.
2 : 50 times/sec.
1 : 100 times/sec.
0 : 200 times/sec.
At discharging weighing time
1 : Net weight is displayed with
the sign not reversed.
0 : Net weight is displayed with
the sign reversed.
Filter in stable condition
1 : Not insert
0 : Insert (128 times)
Switching Gross weight/Net weight
1 : External input mode
0 : Internal key mode
1 : Checker mode
0 : Stable mode
Motion Detection mode
(For details, please refer to
"5-6" on P.58.)
(For details, please refer to
"5-15" on P.67.)
(For details, please refer to
"5-16" on P.68.)
(For details, please refer to
"5-5" on P.57.)
(For details, please refer to
"10-3-9" on P.140.)
display
7
OVER
8
UNDER
LOCK1
1 : ON
0 : OFF
LOCK2
1 : ON
0 : OFF
One-touch Tare subtraction
1 : Accept only at stable time
0 : Accept regularly
1 : Valid
0 : Invalid
Range of Tare subtraction
1 : 0 Tare Capacity
0 : Total range
Prohibition of Tare Weight
1 : Valid
0 : Invalid
Tare Weight display with
the key
0
and digital tare subtraction
ON/OFF when one-touch
tare subtraction is working.
acceptance condition
9
FINAL

Table of Contents

Other manuals for Unipulse F701-C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Unipulse F701-C and is the answer not in the manual?

Unipulse F701-C Specifications

General IconGeneral
BrandUnipulse
ModelF701-C
CategoryAccessories
LanguageEnglish

Related product manuals