6.DISCHARGING CONTROL MODE
74
0
NET
GROSS
TIME
The Near Zero signal is used for discharge completion confirmation as in the
case of feeding weighing.
Judgment
(Go, Over or Under)
Final – CPS
Lower Limit
Final – SP2
Final – SP1
Raw materials are fed until
Gross for Upper/Lower limit comparison,
and Net for Final, Set Point 2, and Near Zero comparisons.
(In discharging weighing,
Net is compared negatively.)
the upper limit signal is output.
Tare subtraction
SP2
SP1
SP3
Comparison
Judging Timer
Lower Limit
Inhibit Timer