Selection
number
Selection name Description
0 No reset
The last motor potentiometer frequency reference is kept
through the stop state and kept in memory if a powerdown
occurs.
1 Stop state
The motor potentiometer frequency reference is set to 0
when the drive goes to the stop state, or when the drive is
powered down.
2 Powered down
The motor potentiometer frequency reference is set to 0 only
when a powerdown occurs.
9.4 JOYSTICK PARAMETERS
Use the joystick parameters when you control the frequency reference or the torque
reference of the motor with a joystick. To control the motor with a joystick, connect the
joystick signal to an analogue input and set the joystick parameters.
CAUTION!
We recommend strongly that you use the Joystick function with analogue inputs of
the range -10V...+10V. In this case, if a wire breaks, the reference does not go to the
maximum value.
P3.3.5.1 JOYSTICK SIGNAL SELECTION (ID 451)
With this parameter, you can set the analogue input signal that controls the Joystick
function.
Use the Joystick function to control the frequency reference of the drive or the torque
reference.
P3.3.5.2 JOYSTICK DEAD ZONE (ID 384)
To ignore the small values of the reference around 0, set this value to be bigger than 0. When
the analogue input signal is 0 ± the value of this parameter, the joystick reference is set to 0.
VACON · 248 PARAMETER DESCRIPTIONS
9
TEL. +358 (0)201 2121 · FAX +358 (0)201 212 205