EasyManua.ls Logo

Vacon 100 - Multi-Purpose Application Wizard

Vacon 100
342 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
20
Set the signal range of the analogue input
0 = 0…10V / 0…20mA
1 = 2…10V / 4…20mA
21
Set a value for P3.13.2.1 (Keypad Setpoint 1) and
P3.13.2.2 (Keypad Setpoint 2)
Depends on the range set in the question 20.
22
Using the sleep function
0 = No
1 = Yes
If you give the value Yes for the question 22, you see the next 3 questions. If you give the value
No, the wizard is completed.
23
Set a value for P3.34.7 Sleep Frequency Limit Range: 0.00…320.00 Hz
24 Set a value for P3.34.8 Sleep Delay 1 Range: 0…3000 s
25 Set a value for P3.34.9 Wake-up Level The range depends on the set process unit
The PID Control application wizard is completed.
2.5 MULTI-PURPOSE APPLICATION WIZARD
The application wizard helps you to set the basic parameters that are related to the
application.
To start the Multi-purpose application wizard, set the value Multi-purpose to parameter P1.2
Application (ID 212) in the keypad.
NOTE!
If you start the application wizard from the Start-up wizard, the wizard goes directly
to question 11.
1
Set a value for P3.1.2.2 Motor Type (so that it agrees
with the nameplate of the motor)
PM motor
Induction motor
2
Set a value for P3.1.1.1 Motor Nominal Voltage (so
that it agrees with the nameplate of the motor)
Range: Varies
3
Set a value for P3.1.1.2 Motor Nominal Frequency
(so that it agrees with the nameplate of the motor)
Range: 8.00…320.00 Hz
4
Set a value for P3.1.1.3 Motor Nominal Speed (so
that it agrees with the nameplate of the motor)
Range: 24…19200 rpm
5
Set a value for P3.1.1.4 Motor Nominal Current (so
that it agrees with the nameplate of the motor)
Range: Varies