1.4.5 MULTI-PURPOSE APPLICATION
You can use the Multi-purpose application for different processes (for example conveyors)
where a wide range of motor control functions is necessary.
It is possible to control the drive from the keypad, Fieldbus or I/O terminal. When you use I/O
terminal control, the start/stop commands are given through DI1 and DI2, and the frequency
reference from AI1 or AI2.
There are 2 acceleration/deceleration ramps available. The selection between Ramp1 and
Ramp2 is made by DI6.
It is possible to configure all the drive outputs freely in all the applications. There are 1
analogue output (Output Frequency) and 3 relay outputs (Run, Fault, Ready) available on the
basic I/O board.
QUICK STARTUP GUIDE VACON · 45
24-HOUR SUPPORT +358 (0)201 212 575 · EMAIL: VACON@VACON.COM