ID 1754 Operating Time Counter (years)
•
ID 1755 Operating Time Counter (days)
•
ID 1756 Operating Time Counter (hours)
•
ID 1757 Operating Time Counter (minutes)
•
ID 1758 Operating Time Counter (seconds)
Example: You receive the value 1a 143d 02:21 of the operating time counter from the fieldbus.
•
ID1754: 1 (years)
•
ID1755: 143 (days)
•
ID1756: 2 (hours)
•
ID1757: 21 (minutes)
•
ID1758: 0 (seconds)
9.19.2 OPERATING TIME TRIP COUNTER
The operating time trip counter of the control unit can be reset. It is in the submenu Trip
counters. It is possible to reset the counter with the PC, the control panel, or the fieldbus.
The value of the counter has 5 different 16-bit values. To read the value of the counter
through fieldbus, use these ID numbers.
•
ID 1766 Operating Time Trip Counter (years)
•
ID 1767 Operating Time Trip Counter (days)
•
ID 1768 Operating Time Trip Counter (hours)
•
ID 1769 Operating Time Trip Counter (minutes)
•
ID 1770 Operating Time Trip Counter (seconds)
Example: You receive the value 1a 143d 02:21 of the operating time trip counter from the
fieldbus.
•
ID1766: 1 (years)
•
ID1767: 143 (days)
•
ID1768: 2 (hours)
•
ID1769: 21 (minutes)
•
ID1770: 0 (seconds)
ID 2311 OPERATING TIME TRIP COUNTER RESET
You can reset the operating time trip counter with the PC, the control panel, or the fieldbus.
If you use the PC or the control panel, reset the counter in the Diagnostics menu.
If you use the fieldbus, to reset the counter, set a rising edge (0 => 1) to ID2311 Operating
Time Trip Counter Reset.
9.19.3 RUN TIME COUNTER
The run time counter of the motor cannot be reset. It is in the submenu Total counters. The
value of the counter has 5 different 16-bit values. To read the value of the counter through
fieldbus, use these ID numbers.
PARAMETER DESCRIPTIONS VACON · 315
24-HOUR SUPPORT +358 (0)201 212 575 · EMAIL: VACON@VACON.COM
9