Chapter 8 System Options Alpha Compact 32708612
Version: 14.12.2012 page 105 of 135
022 HOME TIMEOUT
This adjustment determines the maximum time the applicator waits for the signal of the
home position sensor during retract movement before an error message is indicated. This
is also valid after switching on the labeler in case the tamp does not move to home posi-
tion because e.g. air pressure has not yet been connected.
Push [Enter] to edit the configuration parameter (in case of password query see
page 91).
Push the *buttons [] or [] to increase or reduce the parameter value
(unit = value x 100ms, value "000" = no query of home position, value "255"
= waits indefinitely for home position signal).
Push [Enter] to save the value.
Push the buttons [] or [] to get to the next configuration parameter.
Push [Start] or [Stop] to leave the parameter setting.
023 BARCODE READ TIME
This adjustment determines the maximum time the applicator waits for the signal of the
BARCODE reader before an error message is indicated.
Push [Enter] to edit the configuration parameter (in case of password query see
page 91).
Push the *buttons [] or [] to increase or reduce the parameter value
(unit = value x 100ms, value "000" = no query of home position, value "255"
= waits indefinitely for home position signal).
Push [Enter] to save the value.
Push the buttons [] or [] to get to the next configuration parameter.
Push [Start] or [Stop] to leave the parameter setting.
*Fast forward-function when pushing the button [] or [].
CONFIGURATION 022
HOME TIMEOUT 000
CONFIGURATION 023
BARCODE READ TIME 000