EasyManuals Logo

Weber ALPHA COMPACT User Manual

Weber ALPHA COMPACT
136 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #92 background imageLoading...
Page #92 background image
Chapter 8 System Options Alpha Compact 32708612
Version: 14.12.2012 page 92 of 135
002 LABEL POSITION (LABEL POS.)
Herewith the label position to the peeler bar is adjusted manually. There is the possibility
of automatic label calibration.
Push [Enter] to edit the configuration parameter (in case of password query see
page 91).
Push the *buttons [] or [] to increase or reduce the value.
Push [Enter] to confirm the entry.
Push [Start] or [Stop] to leave the parameter setting.
* Fast forward-function when pushing the button [] or [].
003 SPEED (SPEED)
Here the application rate is adjusted. This speed should correspond to the speed at which
the product is transferred to the labeler. By using a rotating shaft encoder there is the
possibility that the controller identifies automatically the product speed and also reacts on
varying product speeds.
Push [Enter] to edit the configuration parameter (in case of password query see
page 91).
Push the *buttons [] or [] to increase or reduce the value.
Push [Enter] to confirm the entry.
Push [Start] or [Stop] to leave the parameter setting.
CONFIGURATION 02
LABEL POSITION cm: 11,8
CONFIGURATION 03
SPEED m/min: 0.50