Chapter 8 System Options Alpha Compact 32708612
Version: 14.12.2012 page 99 of 135
014 VACUUM TIMEOUT: 200
This parameter determines the maximum time delay the Alpha Compact will try to detect
label presence on tamp by sensing the vacuum in the tamp before generating an error
message. This means the achievable vacuum has to be complete within the adjusted
time, otherwise an error occurs. Normally the vacuum is controlled after printing proce-
dure. For particular applications, the value can be set to “000” whereby the examination of
the vacuum is started together with printing.
Push [Enter] to edit the configuration parameter (in case of password query see
page 91).
Push the *buttons [] or [] to increase or reduce the parameter value.
(unit = value x 10ms, value = "0" abrupt vacuum testing, in case of value =
"255" the labeler waits indefinitely until the vacuum was set up (200 = 2
seconds = default).
Push [Enter] to save the value.
Push the buttons [] or [] to get to the next configuration parameter.
Push [Start] or [Stop] to leave the parameter setting.
**Fast forward-function when pushing the button [] or [].
CONFIGURATION 014
VACUUM TIMEOUT 200