Maintenance
7218−1/A1
Winterthur Gas & Diesel Ltd.
1/ 6
Cylinder Lubrication System
1. Cylinder Lubricating System 1.......................................
1.1 Cylinder Lubricating System − Operate 1.......................
1.2 Function Check 3.............................................
2. Flex Lube Pump 3..................................................
2.1 Checks 3.....................................................
2.2 Manual Release − One Lube Pulse 3............................
3. Cylinder Lubricating System − Bleed 4...............................
3.1 Flex Lube Pump 4.............................................
3.2 Oil Pipes 4...................................................
4. Duplex Filter 5......................................................
4.1 Clogged Filter Element − Replace 5............................
4.2 Filter Element − Clean 5.......................................
1. Cylinder Lubricating System
For more data about the cylinder lubricating system, see Operation Manual, 7218-1.
1.1 Cylinder Lubricating System − Operate
For more data, see Operation Manual, 4002-2, paragraph 3.2 and paragraph 3.8.
1) In the LDU-20, get the MAIN page.
2) In the navigation menu, select Cylinder Lubrication.
3) In the CYL. LUBRICATION page, field Manual lub. to Cyl. #, select the applicable
cylinder number.
Note: If necessary, change the number of lube pulses (in the range 0 to 200) in
the field # of Manual Lub. Pulses.
Note: As an alternative, you can operate manually the 4/2-way solenoid valve (4,
Fig. 1). For more data, see paragraph 2.2.