EasyManuals Logo

WTI TSM Series User Manual

WTI TSM Series
224 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #94 background imageLoading...
Page #94 background image
5-65
Basic Configuration
ServiceAccess: Selects the default Service Access setting for new TACACS
users. The Service Access setting determines whether each account will be able
to access command mode via Serial Port, Telnet/SSH or Web. For example,
if Telnet/SSH Access is disabled for an account, then the account will not be
able to access command mode via Telnet or SSH. (Default = Serial Port = On,
Telnet/SSH = On, Web = On)
Current/PowerMetering: (RSM-8R8-CM Series Units Only) Determines
whether or not new TACACS users will be allowed to access current metering
and power metering functions by default. (Default = Off)
PingTest(PingTACACSServers): Allows you to ping IP addresses or domain
names that have been defined via the TACACS Parameters menus in order to check
that a valid IP address or domain name has been entered.
Notes:
• InorderforthePingTestfeaturetofunction,yournetworkand/orfirewall
mustbeconfiguredtoallowpingcommands.
• InadditiontothePingTestfeature,the/TESTcommandintheTextInterface
orthe"Test"optionintheWebBrowserInterfacecanalsobeusedtoping
anyuserdefinedIPaddressinordertomakecertainthattheIPaddressis
responding.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the WTI TSM Series and is the answer not in the manual?

WTI TSM Series Specifications

General IconGeneral
BrandWTI
ModelTSM Series
CategoryRemote Control
LanguageEnglish

Related product manuals