5-65
Basic Configuration
ServiceAccess: Selects the default Service Access setting for new TACACS
users. The Service Access setting determines whether each account will be able
to access command mode via Serial Port, Telnet/SSH or Web. For example,
if Telnet/SSH Access is disabled for an account, then the account will not be
able to access command mode via Telnet or SSH. (Default = Serial Port = On,
Telnet/SSH = On, Web = On)
Current/PowerMetering: (RSM-8R8-CM Series Units Only) Determines
whether or not new TACACS users will be allowed to access current metering
and power metering functions by default. (Default = Off)
PingTest(PingTACACSServers): Allows you to ping IP addresses or domain
names that have been defined via the TACACS Parameters menus in order to check
that a valid IP address or domain name has been entered.
Notes:
• InorderforthePingTestfeaturetofunction,yournetworkand/orfirewall
mustbeconfiguredtoallowpingcommands.
• InadditiontothePingTestfeature,the/TESTcommandintheTextInterface
orthe"Test"optionintheWebBrowserInterfacecanalsobeusedtoping
anyuserdefinedIPaddressinordertomakecertainthattheIPaddressis
responding.