077-905 Feed Out Sensor 3 Static Jam
Status Indicator RAPs
Version 1.0
077-905 Feed Out Sensor 3 Static Jam
BSD-ON: CH8.3
Feed Out Sensor 3 On was detected during Standby.
Initial Actions
Refer to the BSD and check the related connectors of the target electrical parts for partial con-
nections.
Cause/Action
Check the following:
• The Feed Out Sensor 3 for remaining paper, Actuator return failure, foreign substances,
contamination on sensor, and etc.
• Feed Out Sensor 3: Input Check [072-109] (PL 11.5)
If no problems are found, replace the 2TM PWB (PL 11.6).
077-906 Feed Out Sensor 4 Static Jam
BSD-ON: CH8.3
Feed Out Sensor 4 On was detected during Standby.
Initial Actions
Refer to the BSD and check the related connectors of the target electrical parts for partial con-
nections.
Cause/Action
Check the following:
• The Feed Out Sensor 4 for remaining paper, Actuator return failure, foreign substances,
contamination on sensor, and etc.
• Feed Out Sensor 4: Input Check [072-112] (PL 11.5)
If no problems are found, replace the 2TM PWB (PL 11.6).