06/2014
2-139
WC 5022/5024
093-956 Drum New CRU Installation Fail
Status Indicator RAPs
Version 1.0
093-956 Drum New CRU Installation Fail
BSD-ON: CH9.2
During the developing powder installation mode after installing the Drum Cartridge, the ATC
Measured Value is found to be abnormal. (Seal not removed)
Cause/Action
1. Remove the developing powder seal from the Drum Cartridge.
2. If the problem persists after removing the seal, replace the ATC Sensor. (PL 8.6)
3. If the problem persists, replace the Drum Cartridge. (PL 8.1)
NOTE: After replacing the Drum Cartridge, clear the HFSI [950-807] (Drum Cycle
Counter) to '0'.
093-959 Drum New CRU Installation Fail Exceeds
Thresholding Times
BSD-ON:-
The number of developing powder installation mode executions has exceeded the upper limit.
Cause/Action
Replace it with the correct Drum Cartridge. (PL 8.1)
NOTE: After replacing the Drum Cartridge, clear the HFSI [950-807] (Drum Cycle Counter) to
'0'.