06/2014
2-155
WC 5022/5024
134-210 Fax Data Parameter Error
Status Indicator RAPs
Version 1.0
134-210 Fax Data Parameter Error
BSD-ON:-
Any one of Parameter Type Error, Parameter Data Error, or Parameter Length Error received
from the Fax Board.
Cause/Action
1. Turn the power OFF and ON.
2. Perform NVM Initialize in the CE Mode. For details on the NVM Initialize, refer to '6.5.2.4
NVM Initialize'.
3. If the problem persists, replace the Fax PWB (PL 18.5).
134-211 Fax Board Failure
BSD-ON:-
Fax Board malfunction (Memory Error, Hardware Error) received from the Fax Board.
Cause/Action
1. Turn the power OFF and ON.
2. Print out the Error Report and then replace the Fax PWB (PL 18.5).
3. Re-send the Fax or request for the customer to receive one.