2.2.4.8 NIP/RELEASE SOLENOID Not Energized
Status Indicator RAPs
Version 1.0
YN
Replace the NIP/RELEASE SOLENOID.
Check the connection between the PWB pin-6 and the NIP/RELEASE SOLENOID pin-2
for an open circuit and poor contact.
Replace the PWB.