4 SERVOPACK Specifications and Dimensional Drawings
4-18
* 3. An external regenerative resistor must be connected to SERVOPACKs with a capacity of 6.0 kW or
higher. The following regenerative resistor units are provided for this purpose.
For the SGDH-60AE: JUSP-RA04 (allowable loss: 180W)
For the SGDH-60DE and 75DE: JUSP-RA18 (allowable loss: 180W)
For the SGDH-75AE to 1EAE: JUSP-RA05 (allowable loss: 350W)
For the SGDH-1ADE and 1EDE: JUSP-RA19 (allowable loss: 350W)
Note: Refer to 6.5 Connecting Regenerative Resistors, 5.8.6 External Regenerative Resistor and 5.8.7
Regenerative Resistor Unit for details.