6.4 Others
6-23
6
6.4.3 Installation Conditions of EMC Directives
To adapt a combination of a SGMH servomotor and a SGDH SERVOPACK to EMC Directives (EN50081-2
and EN50082-2), the following conditions must be satisfied.
(1) EMC Installation Conditions
This section describes the installation conditions that satisfy EMC guidelines for each model of the SGDH SER-
VOPACK. The conditions required for the standard type (base mounted) of SERVOPACK are described. Refer
to this section for other SERVOPACK models such as the rack mounted types as well.
This section describes the EMC installation conditions satisfied in test conditions prepared by Yaskawa. The
actual EMC level may differ depending on the actual system’s configuration, wiring, and other conditions.
(a) Single-phase 100 V/200 V/220 V
SGDH-A3BE to -02BE (Single-phase 100 VAC, 30 to 200 W)
SGDH-A3AE to -04AE (Single-phase 200 VAC, 30 to 400 W)
SGDH-08AE-S (Single-phase 220 VAC, 750 W)
SGDH-15AE-S (Single-phase 220 VAC, 1.5 kW)
* Connect main circuit power supply to terminals L1-L3 for SGDH-08AE-S and
SGDH-15AE-S.
Symbol Cable Name Specifications
c
I/O Signals cable Shield cable
d
Servomotor cable Shield cable
e
Encoder cable Shield cable
f
AC Line cable Shield cable

 



PE
PE
CN2
CN1
U, V, W
L1, L2
L1C, L2C
Brake
Servo-
motor
Encoder
Ground Plate / Shield Box
Clamp
Core
Approx. 5 m (16.4 ft)
Core
Core
Core
Clamp
SERVOPACK
Brake power
supply
Core
Core
Host controller
Noise
filter
Noise
filter
Clamp
Approx. 2 m (6.56 ft)
Power Supply
Single-phase
100 VAC or 200 VAC

Table of Contents

Related product manuals