EasyManua.ls Logo

YASKAWA SGDH - Regenerative Resistor Unit

YASKAWA SGDH
616 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5.8 Peripheral Devices
5-71
5
(4) Dimensional Drawings
5.8.7 Regenerative Resistor Unit
(1) Models
The SERVOPACKs with a capacity of 6.0 kW or more do not have a built-in regenerative resistor.
The following regenerative resistor unit is required according to the SERVOPACK model.
RH120/150/220 RH220B
RH300C RH500
A
B
G
F
E
3.5 (0.14)
4.5 
(0.18)
D
D
C
φ4.5 (φ0.18)
Lead wire length L: 300 (11.81)
A B C D E F G
RH120 182 150 172 16 42 22 20
(7.17) (5.91) (6.77) (0.63) (1.65) (0.87) (0.79)
(8.35) (7.09) (7.95) (0.63) (1.73) (0.94) (1.18)
(9.06) (7.87) (8.66) (0.59) (2.36) (0.94) (0.79)
RH150 212 180 202 16 44 24 30
RH220 230 200 220 15 60 24 20
RH120 70 W 1 to 100
RH150 90 W 1 to 100
RH220 120 W 1 to 100
Rated PowerModel
Dimensions
Units: mm (in)
Resistance
138 (5.43)
170 (6.69)
φ4.5 (φ0.18)
4
154 (6.06)
30 (1.18)
60 (2.36)
54 (2.13)
40 (1.57)
3.0 (0.12)
Lead wire length L: 500 (19.69)
Rated power: 120 W
Resistance: 1 to100
Units: mm (in)
×
62 (2.44)
37 (1.46)
47
(1.85)
32
(1.26)
33
(1.30)
5.3
(0.21)
4.7 (0.19)
312 (12.28)
300 (11.81)
270 (10.63)
Lead wire length L: 300 (11.81)
Rated power: 200 W
Resistance: 1 to 10 k
Units: mm (in)
3
(0.12)
250 (9.84)
234 (9.21)
218 (8.58)
60
(2.36)
80 (3.15)
4.5 (0.18)
40 (1.57)
2
×
φ4.5 (φ0.18)
2 - M3
Lead wire length L: 450 (17.72)
Rated power: 300 W
Resistance: 1 to 30
Units: mm (in)
SERVOPACK Model Regenerative Resistor
Unit Model
Specifications Allowable
Power Loss
SGDH-60AE
JUSP-RA04 6.25 , 880 W 180 W
SGDH-75AE to -1EAE
JUSP-RA05 3.13 , 1760 W 350 W
SGDH-60DE to -75DE
JUSP-RA18 18 , 880 W 180 W
SGDH-1ADE to -1EDE
JUSP-RA19 14.25 , 1760 W 350 W

Table of Contents

Related product manuals