6.4 Others
6-31
6
Single-phase Power Supply Connection Example
6.4.8 DC Reactor for Harmonic Suppression
(1) Reactor Types
The SERVOPACK has the DC reactor connection terminals for power supply harmonic suppression. However,
SERVOPACKs with capacities of 6 kW or more do not have these terminals. The type of DC reactor to be con-
nected differs depending on the SERVOPACK capacity. Refer to the following table.
Note: Select a proper DC reactor for the input current to the SERVOPACK.
Refer to 2.6.2 Molded-case Circuit Breaker and Fuse Capacity for input current to each
SERVOPACK. For the kind of reactor, refer to 5.8.13 DC Reactor for Harmonic Suppres-
sion.
Single-phase
Magnetic contactor for
power supply ON and OFF
Voltage conversion
transformer
100 or 200 VAC
SERVOPACK
R
S
T
1KM
1KM
L1
L2
Applicable
SERVOPACK Model
SGDH-
DC Reactor
Model
Reactor Specifications
Inductance (mH) Rated Current (A)
Single-phase
100 V
A3BE −−
A5BE
01BE X5063 10.0 1.8
02BE X5062 4.7 3.5
Single-phase
200 V
A3AE −−
A5AE
01AE X5071 40.0 0.85
02AE X5070 20.0 1.65
04AE X5069 10.0 3.3
Single-phase
220 V
08AE-S X5079 4.0 5.3
15AE-S X5078 2.5 10.5
Three-phase
200 V
05AE X5061 2.0 4.8
08AE
10AE
15AE X5060 1.5 8.8
20AE
30AE X5059 1.0 14.0
50AE X5068 0.47 26.8
Three-phase
400 V
05DE X5074 4.7 1.5
10DE X5075 3.3 4.5
15DE
20DE X5076 2.2 8.6
30DE
50DE X5077 1.5 14.1