5.2 Servomotor Main Circuit Wire Size and Connectors
5-19
5
5.2.7 SGMDH Servomotor (2000 min
-1
) Connectors for Standard Environments
(1) 200 V Servomotors With and Without Holding Brakes
(2)
Servomotor Main Circuit Connector Pin Arrangement
5.2.8 SGMUH Servomotor (6000 min
-1
) Connectors for Standard Environments
(1) 400 V Servomotors Without Holding Brakes
Capacity
(kW)
Connector on
Servomotor
Plug
Cable Clamp
Straight L-shaped
2.2
3.2
4.0
MS3102A24-10P MS3106B24-10S MS3108B24-10S MS3057-16A
Capacity
(kW)
Connector on
Servomotor
Plug
Cable Clamp
Straight L-shaped
1.0
1.5
MS3102A18-10P MS3106B18-10S MS3108B18-10S MS3057-10A
3.0
4.0
MS3102A22-22P MS3106B22-22S MS3108B22-22S MS3057-12A
Servomotor-end
connector
A
B
C
D
Phase U
Phase V
Phase W
FG
(Frame Ground)
Pin No. Signal
E *
F *
G
Brake terminal
Brake terminal
Pin No. Signal
Without Brakes
A
B
C
D
Phase U
Phase V
Phase W
FG
(Frame Ground)
Pin No. Signal
D
B
G
C
AF
E
With Brakes
* No polarity
D
BC
A