5 Specifications and Dimensional Drawings of Cables and Peripheral Devices
5.8.13 DC Reactor for Harmonic Suppression
5-86
5.8.13 DC Reactor for Harmonic Suppression
(1) Specifications
DC reactor for harmonic suppression is handled by Yaskawa Controls Co., Ltd.
If necessary for harmonic suppression, connect a DC reactor to the SERVOPACK. Note that no terminal for con-
necting a DC reactor is provided to the 6.0 kW or more SERVOPACKs.
Refer to the table below for selecting a DC reactor according to the SERVOPACK capacity. For the connection
method, refer to 6.4.8 DC Reactor for Harmonic Suppression.
Applicable
SERVOPACK Model
SGDH-
DC Reactor
Model
DC Reactor Specifications
Inductance
(mH)
Rated
Current
(A)
Single-phase
100 V
A3BE
−−−
A5BE
01BE
X5063 10.0 1.8
02BE
X5062 4.7 3.5
Single-phase
200 V
A3AE
−−−
A5AE
01AE
X5071 40.0 0.85
02AE
X5070 20.0 1.65
04AE
X5069 10.0 3.3
Single-phase
220 V
08AE-S
X5079 4.0 5.3
15AE-S
X5078 2.5 10.5
Three-phase
200 V
05AE
X5061 2.0 4.8
08AE
10AE
15AE
X5060 1.5 8.8
20AE
30AE
X5059 1.0 14.0
50AE
X5068 0.47 26.8
Three-phase
400 V
05DE
X5074 4.7 1.5
10DE
X5075 3.3 4.5
15DE
20DE
X5076 2.2 8.6
30DE
50DE
X5077 1.5 14.1