5.2 Servomotor Main Circuit Wire Size and Connectors
5-31
5
(2) 200 V Servomotors With Holding Brakes
Select a cable clamp in accordance with the applied cable diameter.
The straight plug type JA06A-24-10S-J1-EB and L-shaped plug type JA08A-24-10S-J1-EB conform to IP67 Protective
Construction Standard only.
INFO
Capacity
(kW)
Connector on
Servomotor
Plug
Cable Clamp
Applicable Cable
Range in mm (in)
(For reference)
Straight L-shaped
1.0
1.5
2.0
JL04V-2E20-15PE-B JL04V-6A20-15SE-EB JL04V-8A20-15SE-EB
JL04-2022CK(09)
φ 6.5 (φ0.26) to
φ 9.5 (φ0.37)
JL04-2022CK(12)
φ 9.5 (φ0.37) to
φ13.0 (φ0.51)
JL04-2022CK(14)
φ12.9 (φ0.51) to
φ15.9 φ0.63)
3.0
4.0
5.0
JL04V-2E24-10PE-B
JL04V-6A24-10SE-EB
or
JA06A-24-10S-J1-EB
JL04V-8A24-10SE-EB
or
JA08A-24-10S-J1-EB
JL04-2428CK(11)
φ 9.0 (0.35) to
φ12.0 (0.47)
JL04-2428CK(14)
φ12.0 (φ0.47) to
φ15.0 (φ0.59)
JL04-2428CK(17)
φ15.0 (φ0.59) to
φ18.0 (φ0.71)
JL04-2428CK(20)
φ18.0 (φ0.71) to
φ20.0 (φ0.79)

Table of Contents