EasyManua.ls Logo

YASKAWA SGDH - Page 421

YASKAWA SGDH
616 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7 Digital Operator/Panel Operator
7.3.1 Setting Parameters
7-20
(c) Parameter Indications
In this manual, the parameter is explained with using the following format.
The following alarm shows the setting value of the parameter.
Decimal display in five digits
Pn406
Emergency Stop Torque
Setting Range
0 to 800 1% 800 Immediately
Setting Unit Factory Setting Setting Validation
The number of the 
parameter
The name of the 
parameter
Position
Positoin
Speed
Torque
Torque
Applicable control mode for the parameter
Speed
: Speed control, internal set speed control
: Position control
: Torque control
This section shows the 
range of the parameter
settings. The maximum 
value can be set even if 
the parameter is combined 
with the other sepecified 
motor.
This section shows the 
minimum setting unit 
(the setting value).
This section shows the 
SERVOPACK's parameter 
with factory setting.
This section shows if 
the setting is validated
"immediately" or "after
restart" when changing
the parameter.

Table of Contents