xvii
4  SERVOPACK Specifications and Dimensional Drawings
4.1  SERVOPACK Ratings and Specifications - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-3
4.1.1  Single-phase 100 V - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -  4-3
4.1.2  Single-phase/Three-phase 200 V - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -  4-3
4.1.3  SERVOPACK Ratings and Specifications  - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -  4-4
4.2  SERVOPACK Installation  - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-6
4.3  SERVOPACK Internal Block Diagrams - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-8
4.3.1  Single-phase 200 V, 30 W to 400 W, and 100 V, 30 W to 200 W Models- - - - - - - - - - - - - - - -  4-8
4.3.2  Three-phase 200 V, 500 W to 1.5 kW Models- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -  4-9
4.3.3  Three-phase 200 V, 2.0 kW to 5.0 kW Models - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -  4-9
4.3.4  Three-phase 200 V, 6.0 kW to 15 kW Models- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -  4-10
4.4  SERVOPACK’s Power Supply Capacities and Power Losses - - - - - - - - - - - - - 4-11
4.5  SERVOPACK Overload Characteristics and Allowable Load Moment of Inertia  4-12
4.5.1  Overload Characteristics  - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-12
4.5.2  Starting and Stopping Time- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -  4-13
4.5.3  Load Moment of Inertia  - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-13
4.6  SERVOPACK Dimensional Drawings - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4-16
4.7  Dimensional Drawings of Base-mounted SERVOPACK Model - - - - - - - - - - - - 4-17
4.7.1  Single-phase 100 V: 30 W to 100 W (A3BD to 01BD, A3BDA to 01BDA)
Single-phase 200 V: 30 W to 200 W (A3AD to 02AD, A3ADA to 02ADA)  - - - - - - - - - - - - - -  4-17
4.7.2  Single-phase 100 V: 200 W (02BD, 02BDA)
Single-phase 200 V: 400 W (04AD, 04ADA)  - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -  4-18
4.7.3  Three-phase 200 V: 500 W/750 W/1.0 kW (05AD to 10AD, 05ADA to 10ADA)  - - - - - - - - - -  4-19
4.7.4  Three-phase 200 V: 1.5 kW (15AD, 15ADA)  - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -  4-20
4.7.5  Three-phase 200 V: 2.0 kW/3.0 kW (20AD to 30AD, 20ADA to 30ADA) - - - - - - - - - - - - - - -  4-21
4.7.6  Three-phase 200 V: 5.0 kW (50ADA)  - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -  4-22
4.7.7  Three-phase 200 V: 6.0 kW/7.5 kW (60ADA to 75ADA)  - - - - - - - - - - - - - - - - - - - - - - - - - -  4-23
4.7.8  Three-phase 200 V: 11.0 kW/15.0 kW (1AADA to 1EADA)  - - - - - - - - - - - - - - - - - - - - - - - -  4-24
4.8  Dimensional Drawings of Rack-mounted SERVOPACK Model - - - - - - - - - - - - 4-25
4.8.1  Single-phase 100 V: 30 W/50 W/100 W (A3BD-R to 01BD-R, A3BDA-R to 01BDA-R)
Single-phase 200 V: 30 W/50 W/100 W/200 W  
(A3AD-R to 02AD-R, A3ADA-R to 02ADA-R)- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -  4-25
4.8.2  Single-phase 100 V: 200 W (02BD-R, 02BDA-R)
Single-phase 200 V: 400 W (04AD-R, 04ADA-R) - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -  4-26
4.8.3  Three-phase 200 V: 500 W/750 W/1.0 kW (05AD-R to 10AD-R, 05ADA-R to 10ADA-R)  - - -  4-27
4.8.4  Three-phase 200 V: 1.5 kW (15AD-R, 15ADA-R) - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -  4-28
4.8.5  Three-phase 200 V: 2.0 kW/3.0 kW (20AD-R to 30AD-R, 20ADA-R to 30ADA-R)  - - - - - - - -  4-29
4.8.6  Three-phase 200 V: 5.0 kW (50ADA-R) - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -  4-30
4.9  Dimensional Drawings of Duct-ventilated SERVOPACK Model - - - - - - - - - - - - 4-31
4.9.1  Three-phase 200 V: 6.0 kW/7.5 kW (60ADA-P to 75ADA-P) - - - - - - - - - - - - - - - - - - - - - - -  4-31
4.9.2  Three-phase 200 V: 11.0 kW/15.0 kW (1AADA-P/1EADA-P) - - - - - - - - - - - - - - - - - - - - - - -  4-32
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com