At proper function, all bits of this bit memory byte are "0". At errors an error code is
entered. The error setting is self-acknowledging, i.e. after elimination of the error cause,
the byte is set back to "0" again. The following errors may occur:
n 1 = Data block not present
n 2 = Data block too short
n 3 = Data block number outside valid range
These parameters are internally used. They serve the information exchange between the
handling blocks. For the deployment of the SYNCHRON_RESET (FC 9) the control bits
LETZTER_BLOCK, EMPF_LAEUFT and FEHLER_EMPF must always be stored in a bit
memory byte.
PAFE
GEEM, ANZ_INT,
LETZTER_BLOCK,
EMPF_LAEUFT,
FEHLER_EMPF
VIPA SPEED7
Serial Communication
CP240 > FC 11 - ASCII_FRAGMENT - Receive fragmented from CP 240
HB00 | OPL_SP7 | Operation list | en | 18-30 237