3.17 Comparison instructions
Comparing the integer (16bit) in ACCU1-L and ACCU2-L.
RLO=1, if condition is satisfied.
Com-
mand
Operand Parameter Function Length in
words
==I - ACCU2-L = ACCU1-L 1
<>I - ACCU2-L different to ACCU1-L 1
<I - ACCU2-L < ACCU1-L 1
<=I - ACCU2-L <= ACCU1-L 1
>I - ACCU2-L > ACCU1-L 1
>=I - ACCU2-L >= ACCU1-L 1
Status word BR CC1 CC0 OV OS OR STA RLO /FC
Instruction depends on - - - - - - - - -
Instruction influences -
ü ü
0 - 0
ü ü
1
Comparing the integer (32bit) in ACCU1 and ACCU2.
RLO=1, if condition is satisfied.
Com-
mand
Operand Parameter Function Length in
words
==D - ACCU2 = ACCU1 1
<>D - ACCU2 different to ACCU1 1
<D - ACCU2 < ACCU1 1
<=D - ACCU2 <= ACCU1 1
>D - ACCU2 > ACCU1 1
>=D - ACCU2 >= ACCU1 1
Status word BR CC1 CC0 OV OS OR STA RLO /FC
Instruction depends on - - - - - - - - -
Instruction influences -
ü ü
0 - 0
ü ü
1
Comparison instructions
with integer (16bit)
Comparison instructions
with integer (32bit)
VIPA SPEED7
IL operations
Comparison instructions
HB00 | OPL_SP7 | Operation list | en | 18-30 53