13.8.4 Commissioning
13.8.4.1 Transfer project to target device
You can transfer your project to your panel via Ethernet. The Movicon runtime version,
which is pre-installed in your panel, will make your project executable.
1. Connect your PC and your panel via Ethernet.
2. Start your panel and determine the IP address of your panel in the ‘Startup-
Manager .
3. Call in your ‘Startup-Manager the ‘Autostart’ menu item.
4. To enable Movicon to transfer a project to your panel via Ethernet, you have to
enable the option ‘Movicon TCP Upload Server at ‘Autostart’ .
ð
Confirm the query for activation.
5. Now you can transfer your project to your panel from Movicon. For this in Movicon
click in ‘Resources’ at ‘SimpleMotion’ and select ‘Context menu
è Upload project to Device/FTP’.
ð
The Transfer dialog opens.
6. Select at ‘PlugIn Type’ ‘TCP’ .
Specify at ‘Server the IP address of the panel.
Enter at ‘User name’ and ‘Password’ the access for your panel.
The following access data are used per default:
n Username: wince
n Password: vipatp
Specify at ‘Upload Device Path’ you memory card and create a new project direc-
tory.
7. Start the transfer with [Upload project].
8. After successful transfer, you can add your project on the panel in the autostart
directory and start it up.
CAUTION!
Please always observe the safety instructions for your drive, espe-
cially during commissioning!
VIPA SPEED7
Motion control - Simple Motion Control Library
Controlling the drive via HMI > Commissioning
HB00 | OPL_SP7 | Operation list | en | 18-30 629