Parameters
Parameter Declaration Data type Memory block Description
PRGFLT_SET_MASK INPUT DWORD I, Q, M, D, L,
constant
Programming faults that must be
masked out
ACCFLT_SET_MASK INPUT DWORD I, Q, M, D, L,
constant
Access faults that must be masked
out
RET_VAL OUTPUT INT I, Q, M, D, L The return value contains an error
code if an error is detected when the
function is being processed.
PRGFLT_MASKED OUTPUT DWORD I, Q, M, D, L Masked programming faults
ACCFLT_MASKED OUTPUT DWORD I, Q, M, D, L Masked access errors
RET_VAL (Return value)
Value Description
0000h None of the faults has previously been masked.
0001h One or more of the faults has already been masked, however, the other faults will still be
masked out.
14.1.27 SFC 37 - DMSK_FLT - Unmask synchronous errors
The SFC 37 DMSK_FLT (unmask synchronous faults) unmasks any masked synchro-
nous faults. A call to the SFC 37 unmasks the synchronous faults of the current priority
class. The respective bits in the fault mask of the input parameters are set to "1". This
results in new fault masks that you can read via the output parameters. Queried entries
are deleted from in the error register.
Parameters
Parameter Declaration Data type Memory block Description
PRGFLT_RESET_MASK INPUT DWORD I, Q, M, D, L,
constant
Programming faults that must be
unmasked
ACCFLT_RESET_MASK INPUT DWORD I, Q, M, D, L,
constant
Access faults that must be unmasked
RET_VAL OUTPUT INT I, Q, M, D, L The return value contains an error code
if an error is detected when the function
is being processed.
PRGFLT_MASKED OUTPUT DWORD I, Q, M, D, L Masked programming faults
ACCFLT_MASKED OUTPUT DWORD I, Q, M, D, L Masked access errors
Description
VIPA SPEED7
Integrated Standard
System Functions > SFC 37 - DMSK_FLT - Unmask synchronous errors
HB00 | OPL_SP7 | Operation list | en | 18-30 677