Variable Data type Description
OB56_PRIORITY BYTE Configured priority class:
Default value: 2
OB56_OB_NUMBR BYTE OB number (56)
OB56_RESERVED_1 BYTE reserved
OB56_IO_FLAG BYTE Input module: 54h
Output module: 55h
OB56_MDL_ADDR WORD Logical base address of the module that triggers the inter-
rupt
OB56_LEN BYTE Data block length supplied by the interrupt
OB56_TYPE BYTE ID for the interrupt type "Update interrupt"
OB56_SLOT BYTE Slot number of the interrupt triggering component
OB56_SPEC BYTE Specifier:
n Bit 1, 0: Interrupt specifier
n Bit 2: Add_Ack
n Bit 7 ... 3: Seq. number
OB56_DATE_TIME DATE_AND_TIME Date and time of day when the OB was called
You can obtain the full additional information on the interrupt from the
frame by calling SFB 54 "RALRM" in OB 56.
Ä
Chap. 14.2.22 ‘SFB 54 -
RALRM - Receiving an interrupt from a periphery module’ page 777