13.8.3 Modify the project in Movicon
1. Open via ‘Resources > SimpleMotion >Screens’ ‘Screen1’ .
2. Navigate in ‘Browse Folders’ at ‘vipa simple motion control ...’ and drag & drop
from the ‘Library view’ the template to the ‘Screen1’ , which matches the resolution
of your panel.
ð
The initialization dialog opens
3. Specify a name for the axis. Allowed characters: A-Z, a-z, 0-9, space and the sepa-
rators "_" and "-"
Specify the instance DB number that you use in your PLC program.
Specify the station name. This must match the ‘Station Name’ from ‘Station
Properties’ of the ‘S7 TCP’ communication settings. Allowed characters: A-Z, a-z,
0-9, space and the separators "_" and "-"
ð
With [OK] all variables as well as their structures are generated and the
addresses are set to the specified destination address.
4. Place the template and adjust its size.
Variables are created for each template under the corresponding
name. When deleting the template, the corresponding variables
must be deleted again. You can select these at ‘Resources >
SimpleMotion > Real Time DB > Variables’ . Delete these together
with the higher-level directory. If no further templates access the
‘Structure Prototypes’ for the Axis control, these must also be
deleted.
Configuring the screen
VIPA SPEED7
Motion control - Simple Motion Control Library
Controlling the drive via HMI > Modify the project in Movicon
HB00 | OPL_SP7 | Operation list | en | 18-30 619