Parameters
Parameter Declaration Data type Memory block Description
NR INPUT BYTE I, Q, M, D, L,
constant
Input NR contains the number of the run-time
meter that you wish to read.
Range: 0 ... 7
RET_VAL OUTPUT INT I, Q, M, D, L The return value contains an error code if an
error is detected when the function is being pro-
cessed.
CQ OUTPUT BOOL I, Q, M, D, L Output CQ indicates whether the run-time meter
is started or stopped.
n "0": the status of the run-time meter is
stopped.
n "1": the status of the run-time meter is
started.
CV OUTPUT INT I, Q, M, D, L Output CV indicates the up to date value of the
run-time meter.
RET_VAL (Return value)
Value Description
0000h no error
8080h Incorrect number for the run-time meter
8081h run-time meter overflow
14.1.7 SFC 5 - GADR_LGC - Logical address of a channel
The SFC 5 GADR_LGC (convert geographical address to logical address) determines the
logical address of the channel of a I/O module.
Parameter Declaration Data type Memory block Description
SUBNETID INPUT BYTE I, Q, M, D, L,
constant
area identifier
RACK INPUT WORD I, Q, M, D, L,
constant
Rack No.
SLOT INPUT WORD I, Q, M, D, L,
constant
Slot No.
SUBSLOT INPUT BYTE I, Q, M, D, L,
constant
Submodule slot
SUBADDR INPUT WORD I, Q, M, D, L,
constant
Offset in user-data address space of the
module
Description
Parameter
VIPA SPEED7
Integrated Standard
System Functions > SFC 5 - GADR_LGC - Logical address of a channel