4. The operating parameters required for Pulse Train are internally adapted to the cor-
responding values. Leave all values unchanged.
5. Close the dialog with [OK].
6.
Select ‘Project è Compile all’.
13.3.4.2 User program
In the ‘Catalog’ , open the ‘Simple Motion Control’ library at ‘Blocks’ and drag and
drop the following blocks into ‘Program blocks’ of the Project tree:
n Sigma5+7 Pulse Train
FB 875 - VMC_AxisControl_PT
Ä
Chap. 13.3.7.1 ‘FB 875 - VMC_AxisCon-
trol_PT - Axis control via Pulse Train’ page 423
Copy block to project
VIPA SPEED7
Motion control - Simple Motion Control Library
Usage Sigma-5/7 Pulse Train > Usage in VIPA SPEED7 Studio
HB00 | OPL_SP7 | Operation list | en | 18-30 410