1. Click in the Project tree at ‘Devices and networking’ .
ð
You will get a graphical object view of your CPU.
2. Click at the network ‘PG_OP_Ethernet’ .
3.
Select ‘Context menu è Interface properties’.
ð
A dialog window opens. Here you can enter the IP address data for your
Ethernet PG/OP channel. You get valid IP address parameters from your
system administrator.
4. Confirm with [OK].
ð
The IP address data are stored in your project listed in ‘Devices and
networking’ at ‘Local components’ .
After transferring your project your CPU can be accessed via Ethernet PG/OP
channel with the set IP address data.
For the System SLIO CPUs 014 ... 017, the RS485 interface is set to PtP communication
as standard. A hardware configuration to enable the PtP functionality is not necessary.
13.5.4.2 User program
13.5.4.2.1 Program structure
n FB 876 - VMC_ConfigMaster_RTU
Ä
504
This block is used to parametrize the serial interface of the CPU for Modbus RTU
communication.
Internally block SFC 216 - SER_CFG is called.
Configuration of Ethernet
PG/OP channel
Enable PtP functionality
OB 100
OB 1
VIPA SPEED7
Motion control - Simple Motion Control Library
Usage inverter drive via Modbus RTU > Usage in VIPA SPEED7 Studio
HB00 | OPL_SP7 | Operation list | en | 18-30 462