Loading...
Examining the signal state of the addressed timer/counter an gating the result with the
RLO according to the appropriate logic function.
Com-
mand
Operand Parameter Function Length
in words
A AND operation at signal state
T f 0 ... 511 Timer 1/2
C f 0 ... 511 Counter 1/2
Timer para. Timer addressed via parameters 2
Counter para. Counter addressed via parameters 2
AN AND operation at signal state
T f 0 ... 511 Timer 1/2
C f 0 ... 511 Counter 1/2
Timer para. Timer addressed via parameters 2
Counter para. Counter addressed via parameters 2
Status word BR CC1 CC0 OV OS OR STA RLO /FC
Instruction depends on - - - - -
ü
-
ü ü
Instruction influences - - - - -
ü ü ü
1
Com-
mand
Operand Parameter Function Length
in words
O OR operation at signal state
T f 0 ... 511 Timer 1/2
C f 0 ... 511 Counter 1/2
Timer para. Timer addressed via parameters 2
Counter para. Counter addressed via parameters 2
ON OR operation at signal state
T f 0 ... 511 Timer 1/2
C f 0 ... 511 Counter 1/2
Timer para. Timer addressed via parameters 2
Counter para. Counter addressed via parameters 2
Status word BR CC1 CC0 OV OS OR STA RLO /FC
Instruction depends on - - - - - - -
ü ü
Instruction influences - - - - - 0
ü ü
1
Combination instructions
with timer and counters
VIPA SPEED7
IL operations
Combination instructions (Bit)
HB00 | OPL_SP7 | Operation list | en | 18-30 59

Table of Contents