4. A value to be read of a read job may be found in JOB_OVAL in the instance DB at
address 28.
Continuous count:
Job Valid range
Writing counter directly
-2147483647 (-2
31
+1) ... +2147483646 (2
31
-2)
Writing the load value
-2147483647 (-2
31
+1) ... +2147483646 (2
31
-2)
Writing comparison value
-2147483648 (-2
31
) ... +2147483647 (2
31
-1)
Writing hysteresis 0 ... 255
Writing pulse duration* 0 ... 510ms
Single/periodic count, no main count direction:
Job Valid range
Writing counter directly
-2147483647 (-2
31
+1) ... +2147483646 (2
31
-2)
Writing the load value
-2147483647 (-2
31
+1) ... +2147483646 (2
31
-2)
Writing comparison value
-2147483648 (-2
31
) ... +2147483647 (2
31
-1)
Writing hysteresis 0 ... 255
Writing pulse duration* 0 ... 510ms
Single/periodic count, main count direction up:
Job Valid range
End value
2 ... +2147483646 (2
31
-1)
Writing counter directly
-2147483648 (-2
31
) ... end value -2
Writing the load value
-2147483648 (-2
31
) ... end value -2
Writing comparison value
-2147483648 (-2
31
) ... end value -1
Writing hysteresis 0 ... 255
Writing pulse duration* 0 ... 510ms
Single/periodic count, main count direction down:
Job Valid range
Writing counter directly
2 ... +2147483647 (2
31
-1)
Writing the load value
2 ... +2147483647 (2
31
-1)
Writing comparison value
1 ... +2147483647 (2
31
-1)
Writing hysteresis 0 ... 255
Permitted value range for
JOB_VAL
VIPA SPEED7
Integrated Standard
System Function Blocks > SFB 47 - COUNT - Counter controlling
HB00 | OPL_SP7 | Operation list | en | 18-30 764