Offset
Name Length Description
0292h: 0: Rack/station failure, deactivated or not configured
1: Rack/station exists, is activated and has not failed
0692h: 0: All modules of the expansion rack / of a station
exist, are available with no problems and activated.
1: At least 1 module of the expansion rack / of a sta-
tion is not OK or the station is deactivated.
4692h: 0: All modules of a station exist, are available with no
problems, and activated.
1: At least 1 module of a station is not OK or the sta-
tion is deactivated.
0 status_0 1byte Bit 0: Central rack (INDEX = 0) or station 1 (INDEX > 0)
Bit 1: 1. Expansion rack or station 2
... ...
Bit 7: 7. Expansion rack or station 8
1 status_1 1byte Bit 0: 8. Expansion rack or station 9
... ...
Bit 7: 15. Expansion rack or station 16
2 status_2 1byte Bit 0: 16. Expansion rack or station 17
... ...
Bit 5: 21. Expansion rack or station 22
Bit 6: 0 or station 23
Bit 7: 0 or station 24
3 status_3 1byte Bit 0: 0 or station 25
... ...
Bit 5: 0 or station 30
Bit 6: Expansion rack in Siemens S5 area or station 31
Bit 7: 0 or station 32
4 status_4 1byte Bit 0: 0 or station 33
... ...
Bit 7: 0 or station 40
... ... ... ...
15 status_15 1byte Bit 0: 0 or station 121
... ...
Bit 7: 0 or station 128