EasyManuals Logo

Abov MC97F60128 User Manual

Abov MC97F60128
382 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #174 background imageLoading...
Page #174 background image
174
MC97F60128
TnCRH (Timer n Control High Register) : E3H/4079H/4081H/4089H (where n = 3,4,5 and 6)
7
6
5
4
3
2
1
0
TnEN
TnMIE
TnMS1
TnMS0
TnCC
R/W
R/W
R/W
R/W
R/W
Initial value : 00H
TnEN
Control Timer n
0
Timer n disable
1
Timer n enable (Counter clear and start)
TnMIE
Enable or Disable Timer n Match Interrupt
0
Disable
1
Enable
TnMS[1:0]
Control Timer n Operation Mode
TnMS1
TnMS0
Description
0
0
Timer/counter mode (TnO: toggle at A match)
0
1
Capture mode (The A match interrupt can occur)
1
0
PPG one-shot mode (PWMnO)
1
1
PPG repeat mode (PWMnO)
TnCC
Clear Timer n Counter
0
No effect
1
Clear the Timer n counter (When write, automatically
cleared “0” after being cleared counter)
NOTE)
1. Refer to the external interrupt flag 1 register (EIFLAG1) for the T6/T5/T4/T3 interrupt flags.

Table of Contents