Chapter 5 187
Language Reference
CALCulate Subsystem
PDC Mode - <measurement> key words
ACP - no markers
EVM - markers available
OBW - no markers
SPECtrum - markers available
WAVeform - markers available
W-CDMA (3GPP) Mode - <measurement> key words
ACP - no markers
CDPower - markers available
CHPower - no markers
EVMQpsk - markers available
IM - markers available
MCPower - no markers
OBW - no markers
PSTatistic - markers available
RHO - markers available
SEMask - markers available
SPECtrum - markers available
WAVeform - markers available
W-CDMA (Trial & Arib) Mode - <measurement> key words
ACP - no markers
CDPower - markers available
CHPower - no markers
EVMQpsk - markers available
PSTatistic - markers available
RHO - markers available
SPECtrum - markers available
WAVeform - markers available
Example:
Suppose you are using the Spectrum measurement. To position marker
2 at the maximum peak value of the trace that marker 2 is currently on,
the command is:
:CALCulate:SPECtrum:MARKer2:MAXimum
You must make sure that the measurement is completed before trying
to query the marker value. Use the MEASure or READ command
before using the marker command. This forces the measurement to
complete before allowing the next command to be executed.

Table of Contents

Other manuals for Agilent Technologies E4406A VSA Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies E4406A VSA Series and is the answer not in the manual?

Agilent Technologies E4406A VSA Series Specifications

General IconGeneral
BrandAgilent Technologies
ModelE4406A VSA Series
CategoryTest Equipment
LanguageEnglish

Related product manuals