159
Update
Chapter 5
Definin
Output Format
5.4 CODE ID
Up to two characters for Code ID can be configured for each symbology. To make the
Code I D configurat ion easier, the scanner provides five pre-defined Code I D sets t hat you
can select one and m ake necessary changes on it.
I f “Bluet ooth
®
HI D” or “ USB HI D” is configured for interface, Key Type and Key Status
will t hen become applicable. You m ay decide whether or not t o apply Key St atus
when “ Norm al Key” is select ed for Key Type.
Key Type Key Status
Scan Code Only 1 scan code value is allowed. N/ A
Norm al Key Up t o 2 character strings are allowed.
Add Shift
Add Left Ctrl
Add Left Alt
Add Right Ctrl
Add Right Alt
Refer to
Keyboard Wedge Table.
Not e: "] C1" is the Code I D of GS1-128 (EAN- 128) barcodes; "] e0" is the default Code I D
of GS1 DataBar ( RSS) barcodes.
5.4.1 SELECT PRE-DEFINED CODE ID
Apply Code ID Set 1
Apply Code ID Set 2
Apply Code ID Set 3
Apply Code ID Set 4
Apply Code ID Set 5