210
Enter Setup
1663 Barcode Scanner User Guide
#@TRIGOFF<CR>
Purpose To disable t he software trigger
Rem arks
“0x23” + “0x40” + “0x54” + “0x52” + “0x49” + “0x47” + “0x4f” + “0x46” + “0x46”
+ “0x0d”
#@TRIGON<CR>
Purpose To enable the software trigger
Rem arks
“0x23” + “0x40” + “0x54” + “0x52” + “0x49” + “0x47” + “0x4f” + “0x4e” + “0x0d”
#@RDSN<CR>
Purpose Read serial num ber
Rem arks
“0x23” + “0x40” + “0x52” + “0x44” + “0x53” + “0x4E” + “0x0D”
EXAMPLE
You m ay run HyperTerm inal.exe on t he host com puter to send serial com m ands t o t he
scanner via USB Virtual COM or Bluet oot h
®
SPP.
For the scanner t o stop im m ediately
D
For the scanner t o resum e working
E
For the scanner t o change the beeper to m edium volum e and beep
#@101011<CR>
#@////<CR>
For the scanner t o change the beeper to m inim al volum e and beep
#@101010<CR>
#@////<CR>
For the scanner t o change the beeper frequency to 8 kHz (for Good Read Beep only)
and beep
#@101001<CR>
#@////<CR>
For the scanner t o change the beeper length to longest (for Good Read Beep only)
and beep
#@101008<CR>
#@////<CR>
For the scanner t o save t he set t ings, send the serial com m and # @109999
#@101011<CR>
#@109999<CR>