Chapter 4 Troubleshooting Hardware
Troubleshooting Supervisor Issues
dpvm 0 N/A
dstats 1 0
epld_upgrade 0 N/A
epp 1 1
Step 5 Use the show system internal sysmgr service all command on the standby supervisor to determine
whether or not any process is experiencing excessive restarts. (See Example 4-12.)
Note This command may not be available if the standby supervisor is at the loader> prompt.
Example 4-12 Finding Excessive Restarts
switch(standby)# show system internal sysmgr service all
Name UUID PID SAP state Start count
------------ -------- ------ ----- ----- -----------
aaa 0x000000B5 1458 111 s0009 1
ExceptionLog 0x00000050 [NA] [NA] s0002 None
platform 0x00000018 1064 39 s0009 1
radius 0x000000B7 1457 113 s0009 1
securityd 0x0000002A 1456 55 s0009 1
vsan 0x00000029 1436 15 s0009 1
vshd 0x00000028 1408 37 s0009 1
wwn 0x00000030 1435 114 s0009 1
xbar 0x00000017 [NA] [NA] s0017 23
xbar_client 0x00000049 1434 917 s0009 1
Looking at the standby supervisor in Example 4-12 shows that the crossbar (xbar) software component
has been restarted 23 times. This has probably prevented the standby from initializing properly.
Step 6 Use the reload module command to restart the standby supervisor. If the restart fails, use the reload
module 6 force-dlnd command from the active supervisor to force the standby supervisor to netboot off
of the active supervisor.
Standby Supervisor Stays in Powered-Up State
Symptom Standby supervisor stays in powered-up state.
Table 4-9
Symptom Possible Cause Solution
Standby supervisor
stays in powered-up
state.
Standby supervisor did not synchronize
properly with active supervisor.
See the “Verifying That a Standby Supervisor Is in the
Powered-Up State Using Device Manager” section on
page 4-20 or the “Verifying That a Standby Supervisor Is
in Powered-Up State Using the CLI” section on
page 4-20.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco 9134 - MDS Multilayer Fabric Switch and is the answer not in the manual?

Cisco 9134 - MDS Multilayer Fabric Switch Specifications

General IconGeneral
BrandCisco
Model9134 - MDS Multilayer Fabric Switch
CategorySwitch
LanguageEnglish

Related product manuals