Send documentation comments to mdsfeedback-doc@cisco.com
7-4
Cisco MDS 9000 Family Troubleshooting Guide, Release 3.x
OL-9285-05
Chapter 7 Troubleshooting Cisco Fabric Services
Initial Troubleshooting Checklist
fscm Yes Physical
role Yes Physical
radius Yes Physical
fctimer No Physical
syslogd No Physical
callhome No Physical
device-alias Yes Physical
port-security Yes Logical
Total number of entries = 11
The Physical scope means that CFS applies the configuration for that application to the entire switch.
The Logical scope means that CFS applies the configuration for that application to a specific VSAN.
Step 2 Verify the set of switches in which an application is registered with CFS, using the show cfs peers name
application-name for physical scope applications, and the show cfs peers name application-name vsan
vsan-id for logical scope applications.
An example command output for a physical scope application follows:
Switch# show cfs peers name dpvm
Scope : Physical
--------------------------------------------------
Switch WWN IP Address
--------------------------------------------------
20:00:00:0e:d7:0e:bf:c0 10.76.100.51 [Local]
20:00:00:0e:d7:00:3c:9e 10.76.100.52
Total number of entries = 2
Note The show cfs peers name application-name command displays the peers for all VSANs when applied
to a logical application.
An example command output for a logical scope application follows:
Switch# show cfs peers name port-security
Scope :Logical [VSAN 1]
-----------------------------------------------------------
Domain Switch WWN IP Address
-----------------------------------------------------------
236 20:00:00:0e:d7:00:3c:9e 10.76.100.52 [Local]
239 20:00:00:05:30:00:6b:9e 10.76.100.167
101 20:00:00:0d:ec:06:55:c0 10.76.100.205
Total number of entries = 3
Scope :Logical [VSAN 2]
-----------------------------------------------------------
Domain Switch WWN IP Address
-----------------------------------------------------------
239 20:00:00:0e:d7:00:3c:9e 10.76.100.52 [Local]
211 20:00:00:05:30:00:6b:9e 10.76.100.167
110 20:00:00:0d:ec:06:55:c0 10.76.100.205
Total number of entries = 3
Scope :Logical [VSAN 3]
-----------------------------------------------------------
Domain Switch WWN IP Address

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco 9134 - MDS Multilayer Fabric Switch and is the answer not in the manual?

Cisco 9134 - MDS Multilayer Fabric Switch Specifications

General IconGeneral
BrandCisco
Model9134 - MDS Multilayer Fabric Switch
CategorySwitch
LanguageEnglish

Related product manuals